Call 08043819036 78% Response Rate

Send Email

TDS Instruments

Pioneers in the industry, we offer conductivity sensor - atn tds 111, tds indicator - atn tds 18, tds meter(controller) - atn tds 09, digital tds & conductivity meter atn cd 610622, tds sensor - flow cell and tds sensor/ electrode - atn tds 04 from India.
Conductivity Sensor - ATN TDS 111

Conductivity Sensor - ATN TDS 111

Get Latest Price

Product Details:
Usage/ApplicationIndustrial
Display Typedigital
Dimension3
Weightlight
Colormulti
Designstandard
Conductivity Sensor - ATN TDS 111INTRODUCTION
ATN TDS Sensors are designed for fast, easy & trouble free start up. 
These are ideal for measuring the concentration of dissolved solids in water. 
They are provided with an accurate pre-determined factory calibration constants. 
Rugged design & corrosion resistant material keep electrode spacing & surface area constant so cell constant remain stable for long period. 
Durability of material & high resistance to corrosion ensures the long life & require low maintenance.

FEATURE
• Measure concentration of dissolved solids in water
• Accuracy @ 2% FS
• Available with 1 / 0.1 / 0.01 cell constants
• Temperature compensation through Pt 100 sensor
• Flow through assembly in SS 316

Specification
Cell Constant:1 / 0.1 / 0.01
Range:0 to 50 ppm for cell constant 0.01
0 to 500 ppm for cell constant 0.1
0 to 5000 ppm for cell constant 1
Accuracy:± 2% FS
Temperature Range:0 to 150°C
Maximum Pressure:10 kg/cm2
Material of Construction:SS 316
Process Connections:1) ¾” NPT Threaded
2) 1” ASA 150 Flanged
3) 1” Tri-clover
Insertion Length:1) 50 mm for cell constant 0.01
2) 27.5 mm for cell constant 0.1
3) 28 mm for cell constant 1
Mounting:Insertion (Screw-in)
Standard Cable Length:3 mtr.
Weight:0.5 kg
Get Best QuoteRequest A Callback
TDS Indicator - ATN TDS 18

TDS Indicator - ATN TDS 18

Get Latest Price

Product Details:
Usage/ApplicationIndustrial
Accuracyyes
Warranty1 Year
Resolution1 PPM
Weightlight
Dimension3
Display Typedigital
TDS Indicator - ATN TDS 18
It is an economical meter for online measurement of specific TDS of solution using a TDS cell for R.O plant or D.M plant applications. It enables to measure the TDS without manual balancing and specific TDS is read directly on a digital panel. This is available in panel mounting facility in compact size.

Specification
Range:Single range 0 - 2000 ppm (Specify)
Measuring Accuracy:±1% of full Scale in all ranges count @30ºC
Indication:3.5 digit LED display
Calibration:Manual 1 Point
Cell Assembly:Cell with ½” BSP threading
Power Requirement:230VAC±10%, 50 Hz single phase
Retransmission Output:4 to 20 mA Isolated - Optional
Size:96 x 96 x 110mm
Environment:0 to 50ºC
Get Best QuoteRequest A Callback
TDS Meter(CONTROLLER) - ATN TDS 09

TDS Meter(CONTROLLER) - ATN TDS 09

Get Latest Price

Product Details:
Usage/ApplicationIndustrial
Warranty1 Year
Resolution1 PPM
Dimension3
Display Typedigital
Colormultiple
TDS Meter(CONTROLLER)- ATN TDS 09
It is Micro-Controller based meter for online measurement of specific TDS of solution using a TDS cell for RO plant or DM plant applications. 
It enables to measure the TDS without manual balancing and specific TDS is read directly on a digital panel. 
This is available in panel mounting facility in compact size.

Specification
Range:Single Range 19.99 ppt (Specify the Range)
Measuring Accuracy:±1% of FS in all ranges count @30ºC
Indication:3.5 digit LED display
Calibration:Key Pad Calibration
Control Setting:2 Changeover Relay potential Free Contact of 5A (Optional)
Cell Assembly:½” BSP threading
Power Requirement:230VAC±10%, 50 Hz single phase
Retransmission Output:4-20 mA DC (Optional)
Size:96 x 96 x 120 mm
Environment:0 to 50ºC

Get Best QuoteRequest A Callback
Digital TDS & Conductivity Meter ATN CD 610622

Digital TDS & Conductivity Meter ATN CD 610622

Get Latest Price

Product Details:
Usage/ApplicationIndustrial
Warranty2 Year
Resolution0.1 PPM
Weightlight
Dimensionmulti
Display TypeDigital
Digital TDS & Conductivity Meter ATN CD 610622
Owing to our manufacturing facilities, we offer a wide array of Digital TDS & Conductivity ATN CD 610622.This instrument is a reading meter that measures the solution’s TDS & conductivity with the aid of a cell. Without the manual balance, the specific TDS & conductivity can be read on the digital display. Integrated circuits are included in these instruments and that keep the power consumption low.

Specification
Frequency Source:1kHz in built
Selectable Ranges:Conductivity : 0-20μS, 200μs, 2ms & 200ms / cms, TDS : 20ppm, 200ppm, 2ppt & 200ppt
Measuring Accuracy:±1% of F.S. in all ranges ±1 count @ 20°C
Indication:3.5 Digit LED
Calibration:Single Point Manually
Decimal:Automatic selection
Conductivity cell:Approx. 1.0 cell constant with plastic protective cover (optional 0.1 cell)
Power Requirement:230 ± 10% 50 Hz single phase approx
Environment:0 to 50°C
Dimension:205mm x 65mm x 130mm.
Weight:1.5 Kg. in Aluminum Cabinet
Standard Accessories:cell, Stand, Rod, Clamp, Dust Cover & Manual
Get Best QuoteRequest A Callback
TDS Sensor - Flow Cell

TDS Sensor - Flow Cell

Get Latest Price

Product Details:
Usage/ApplicationIndustry
MediaWater
MaterialStainless Steel
AccuracyYes
WeightLight
Designstandard
Shapesquare
TDS Sensor – Flow Cell
Technical Specification
MOC:HDPE
Temp Range:0-80°C
Process Connection for Sensor:½” BSP Female
Process Connection for Sensor:¼” BSP Female
Get Best QuoteRequest A Callback
TDS Sensor/ Electrode - ATN TDS 04

TDS Sensor/ Electrode - ATN TDS 04

Get Latest Price

Product Details:
Accuracyyes
Colorsilver
UseIndustry
PowerElectricity
TDS Sensor/ Electrode - ATN TDS 04
Specification
Body:CPVC
MOC of Electrode:Platinum / Glass
Cell Constant:0.1 / 1.0
Operating Temperature:80°C
Mac Operating Pressure:2.5 Bar
Temp. Compensation:Pt-100 ( Optional)
Process Connection:½” & ¾” BSP Male
Cable:5 Meters
Get Best QuoteRequest A Callback
TDS Sensor/ Electrode - ATN TDS 03

TDS Sensor/ Electrode - ATN TDS 03

Get Latest Price

Product Details:
AccuracyYes
TDS Sensor/ Electrode - ATN TDS 03

Specification
Body:SS 316
MOC of Electrode:Platinum / Glass
Cell Constant:Propreitary
Operating Temperature:100°C
Mac Operating Pressure:5 Bar
Temp. Compensation:Pt-100 ( Optional)
Process Connection:½” & ¾” BSP Male
Cable:5 Meters
Get Best QuoteRequest A Callback