- Home
- ยป
- Our Products
- »
- Conductivity Instruments
Conductivity Instruments
Conductivity Sensors / Electrodes ATN CD 03
Usage/Application | Industrial |
Display Type | digital |
Dimension | 3 |
Weight | light |
Color | silver |
Specification | ||
Body | : | SS 316 |
MOC of Electrode | : | Platinum / Glass |
Cell Constant | : | 0.1 / 1.0 |
Operating Temperature | : | 100°C |
Mac Operating Pressure | : | 5 Bar |
Temp. Compensation | : | Pt-100 ( Optional) |
Process Connection | : | ½” & ¾” BSP Male |
Cable | : | 5 Meters |
Conductivity Sensors ATN CD 111
Usage/Application | Industrial |
Display Type | digital |
Accuracy | yes |
Weight | Light |
Color | Multiple |
Power | Electricity |
Design | standard |
ATN Conductivity Sensors are designed for fast, easy & trouble free start up. These are ideal for measuring the concentration of dissolved solids in water. They are provided with an accurate pre-determined factory calibration constants. Rugged design & corrosion resistant material keep electrode spacing & surface area constant so cell constant remain stable for long period. Durability of material & high resistance to corrosion ensures the long life & require low maintenance.
FEATURE • Measure concentration of dissolved solids in water • Accuracy @ 2% FS • Available with 1 / 0.1 / 0.01 cell constants • Temperature compensation through Pt 100 sensor • Flow through assembly in SS 316 | |||||||||||||||||||||||||||||||||||||||
|
On-line Panel Mounted Conductivity Indicator - ATN CD 18
Usage/Application | Industrial |
Display Type | Digital |
Dimension | 3 |
Weight | light |
Color | multiple |
Design | standard |
Phase | 3 |
I Deal In | New and Second Hand |
INTRODUCTION
It is an economical meter for online measurement of specific Conductivity of solution using a Conductivity cell for RO plant or DM plant applications. It enables to measure the Conductivity without manual balancing and specific Conductivity is read directly on a digital panel. This is available in panel mounting facility in compact size.
SPECIFICATION
Range : 0 ~ 2000 μS/cm (Specify)
Measuring Accuracy : ±1% FS of all Range Counts@30ºC
Indication : 3.5 digit LED display
Cell Assembly : Cell with ½” BSP threading
Power Requirement : 230 V AC ±10%, 50 Hz Single Phase
Size : 96 x 96 x 64 mm
Environment : 0 ~ 50ºC
Conductivity Indicating Controller - ATN CD 09
Usage/Application | Industrial |
Current | 2 A |
Control Type | High Limit |
Pole Type | Double Pole |
Throw Type | Double Throw |
Color | multiple |
Alarm Output | multiple |
INTRODUCTION
It is an economical meter for online measurement of specific Conductivity of solution using a Conductivity cell for RO plant or DM plant applications. It enables to measure the Conductivity without manual balancing and specific Conductivity is read directly on a digital panel. This is available in panel mounting facility in compact size.
SPECIFICATION
Range : 2000 μS/cm or Specify the range
Measuring Accuracy : ±1% of full Scale in all ranges count @30ºC
Indication : 3.5 digit LED display
Calibration : Keypad Calibration
Control Setting : 2 changeover Relay potential free contact of 5 Amps
Power Requirement : 230 V AC±10%, 50 Hz single phase
Output : 4~20 mA DC (Optional)
Size : 96 x 96 x 120 mm
Environment : 0 to 50ºC
Conductivity Indicating Controllers Model: ATN CD 912
Usage/Application | Industrial |
Current | 1 A |
Accuracy | yes |
Control Type | High Limit |
Pole Type | Double Pole |
Throw Type | Double Throw |
ATN Series ATN CD -912 is Conductivity Indicator specially designed for various industrial applications.
These can be used for monitoring Conductivity of a solution.
The measuring range and control points are settable through the keypad on front fascia and control output is available at the rear terminals.
Retransmission output, communication port are additive features of ATN CD -912.
Technical Specifications | ||
Type of Input | : | From Conductivity Electrode |
Cell Constant | : | 1 / 0.1 / 0.01 |
Display | : | 2 x 16 Characters Backlit |
Calibration Range | : | 0 to 100 μS/cm for cell constant 0.01 0 to 1000 μS/cm for cell constant 0.1 0 to 10000 μS/cm for cell constant 1 |
Accuracy | : | Better than + 0.25% F. S. |
Power Supply | : | 1) 24 V DC, External 2) 90 - 250 V AC, 50 Hz +/- 10% |
Power Consumption | : | < 10 VA |
Temperature Drift | : | < 0.01% of F. S. per 0C change |
Response Time | : | < 500 mSec |
Isolation | : | 1.4 KV between Input, Output & Power Supply |
Enclosure | : | 1) DIN Std. 2) Weather-proof, IP-65 3) Flame-proof, IP -65, IIA, IIB CMRI Certified |
Mounting | : | WP enclosure Field Mounted |
Weight | : | 1.5 kg (Approx.) |
Operating Conditions | : | Temperature 0 to 55 0C / Humidity 5 to 95% non condensing |
Retransmission Output | : | 4 to 20 mA Isolated |
Temp Compensation | : | Pt -100 |
Alarm | : | 02 Nos. |
Conductivity Indicating Transmitter - Field - ATN CD 112
Usage/Application | Industrial |
Display Type | digital |
Accuracy | yes |
Dimension | 3 |
Weight | light |
INTRODUCTION
ATN’s Conductivity transmitters are used for various industrial applications. It can accept input from conductivity electrode of cell constant 1 / 0.1 / 0.01 & conductivity signal is transmitted in the form of electrical 4 - 20 mA signal. The on-line conductivity indication is provided through LCD. Span/Zero adjustments are easily accessible.
FEATURE
• On-line measurement
• 2 wire system
• 4-20 mA DC output
• Auto/Manual temperature compensation
• On-Line indication through LCD display
• Flame-proof, IP-65, IIA, IIB CMRI certified housing
SPECIFICATION
Type of Input : From Conductivity Electrode
Cell Constant : 0.01 / 0.1 / 1
Type of Output : 4 - 20 mA DC, 2 wire Isolated
Display : 8 x 1 LCD
Calibration Range : Factory Calibrated
0 to 100 μS/cm for cell constant 0.01
0 to 1000 μS /cm for cell constant 0.1
0 to 10000 μS /cm for cell constant 1
Temperature Compensation : Auto / Manual through RTD, Pt 100 sensor for 0-100°C
Accuracy : ±0.25% FS
Isolation : 1.4 KV between Input, Output & Power Supply
Power Supply : 24 V DC, External
Power Consumption : < 50 mW
Response Time : < 500 mSec
Temperature Coefficient : ±0.01% per °C
Enclosure : 1) Weather-proof, IP-65
2) Flame-proof, IP-65, IIA, IIB CMRI Certified
Dimensions : 135 (H) x 249 (W) including cable gland x 170 (D) in mm approx.
Electrical Connections : 3/4” ET
Mounting : 2” Pipe Mounting
Weight : 1 kg
Operating Conditions : Temperature 0 to 55°C / Humidity 5 to 95% Non-condensing
Conductivity Meter - ATN CD 622
Usage/Application | Industrial |
Display Type | Digital |
Dimension | multi |
Weight | light |
Color | multiple |
Power | Electricity |
Design | standard |
Phase | 3 |
Portable | Yes |
Specification | ||
Frequency Source | : | In built automatically selected |
Selectable Ranges | : | 0-20μS, 200μs, 2ms & 200ms / cms, |
Measuring Accuracy | : | ±1% of F.S. in all ranges ±1 count @ 20°C |
Indication | : | 3.5 Digit LED |
Calibration | : | Single Point Manually |
Decimal | : | Automatic selection |
Conductivity cell | : | Approx. 1.0 cell constant with plastic protective cover (optional 0.1 cell) |
Power Requirement | : | 230 ± 10% 50 Hz single phase approx |
Environment | : | 0 to 50°C |
Dimension | : | 205mmx65mmx130mm. |
Weight | : | 1.5 Kg. in Aluminum Cabinet |
Standard Accessories | : | Conductivity cell, Stand, Rod, Clamp & Manual |
Digital TDS & Conductivity Meter - ATN CD 610622
Usage/Application | Industrial |
Warranty | 1 Year |
Resolution | 1 PPM |
Color | multiple |
Weight | light |
Display Type | digital |
Design | standard |
I Deal In | New and Second Hand |
Owing to our manufacturing facilities, we offer a wide array of Digital ATN & Conductivity ATN CD 610622.This instrument is a reading meter that measures the solution’s TDS & conductivity with the aid of a cell. Without the manual balance, the specific TDS & conductivity can be read on the digital display. Integrated circuits are included in these instruments and that keep the power consumption low
Specification | ||
Frequency Source | : | 1kHz in built |
Selectable Ranges | : | Conductivity : 0-20μS, 200μs, 2ms & 200ms / cms, TDS : 20ppm, 200ppm, 2ppt & 200ppt |
Measuring Accuracy | : | ±1% of F.S. in all ranges ±1 count @ 20°C |
Indication | : | 3.5 Digit LED |
Calibration | : | Single Point Manually |
Conductivity cell | : | Approx. 1.0 cell constant with plastic protective cover (optional 0.1 cell) |
Power Requirement | : | 230 ± 10% 50 Hz single phase approx |
Environment | : | 0 to 50°C |
Dimension | : | 205mmx65mmx130mm. |
Weight | : | 1.5 Kg. in Aluminum Cabinet |
Standard Accessories | : | Cell, Stand, Rod, Clamp, Dust Cover & Manual |
Conductivity Probe with Platinum Sensors - ATN 3411
Usage/Application | Industrial |
Display Type | digital |
Accuracy | yes |
Dimension | 3 |
Weight | light |
Overview
ATN 3411 measures Conductivity, TDS, NaCl and temperature. In extended conductivity and TDS ranges (up to 500 mS/cm and 400 g/L respectively) the instrument automatically chooses the best scale.
This instrument utilizes a 4-ring potentiometric probe with platinum sensors that offers greater versatility over typical amperometric designs. By utilizing the 4-ring method, it is possible to measure very low or high conductivity levels without
changing probes.
Calibration is automatic at 1 point with 6 memorized buffers.
The meter has 3 options for temperature compensation: ATC between 0 to 60.0°C, MTC and NoTC.
Other features include a read lock function, stability indicator, GLP and PC compatibility via optional MS 03111 software.
Features
• Auto-ranging
• 4-ring potentiometric conductivity probe with internal temperature sensor
• Automatic (ATC), Manual (MTC) or No Temperature Compensation (NoTC)
• Good Laboratory Practice
• PC compatible
Specifications : |
Range: (Conductivity) 0.00 to 29.99 μS/cm; 30.0 to 299.9 μS/cm; 300 to 2999 μS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (actual Conductivity) |
Multi-range Conductivity Meter - ATN 9844
Usage/Application | Industrial |
Display Type | digital |
Accuracy | yes |
Dimension | 3 |
Weight | light |
Color | multiple |
Designed for QC and Production :
ATN 9844 has been designed specifically for use in areas of production and quality control. It is often necessary to test samples ranging from deionized water to brine.
The rugged probe is made of PVC, which is ideal for indoor and outdoor measurements.
Using one point calibration, it is now possible to obtain accurate readings across a very wide range, from 0.1 to 199.9 ms/cm.
If the temperature of the solution fluctuates, MS 9844, with a built-in temperature sensor and Automatic Temperature Compensation, is the perfect instrument.
As an accessory, ATN 832424 is available. The kit includes a rugged carrying case with a beaker, a calibration screwdriver.
FEATURE :
• Rugged probe for indoor/outdoor measurements
• Allow for calibration across a wide range
• Automatic temperature compensation
| |||||||||||||||||||||||||||||||||
Conductivity Sensor - Flow Cell
Media | Water |
Usage/Application | Industrial |
Display Type | digital |
Accuracy | yes |
Dimension | multi |
Weight | light |
Color | silver |
Technical Specification | ||
MOC | : | HDPE |
Temp Range | : | 0-80°C |
Process Connection for Sensor | : | ½” BSP Female |
Process Connection for Sensor | : | ¼” BSP Female |
Conductivity Sensors / Electrodes ATN CD 04
Usage/Application | Industrial |
Display Type | digital |
Dimension | 3 |
Weight | light |
Specification | ||
Body | : | CPVC |
MOC of Electrode | : | Platinum / Glass |
Cell Constant | : | 0.1 / 1.0 |
Operating Temperature | : | 80°C |
Mac Operating Pressure | : | 5 Bar |
Temp. Compensation | : | Pt-100 ( Optional) |
Process Connection | : | ½” & ¾” BSP Male |
Cable | : | 5 Meters |